[Jan-2022] Latest 5V0-21.21 Exam Dumps for Pass Guaranteed [Q12-Q28]

Share

[Jan-2022] Latest 5V0-21.21 Exam Dumps for Pass Guaranteed

Reliable VMware Certified Master Specialist 5V0-21.21 Dumps PDF Jan 20, 2022 Recently Updated Questions


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Performance-tuning, Optimization, Upgrades
  • Given a scenario, identify the appropriate vSAN upgrade methodology
Topic 2
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution
Topic 3
  • identify the tasks to manape a stretches vSAN cluster
  • Identify the operational tasks required to manape an encrypted vSAN
Topic 4
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Installing, Configuring, ana Setup
Topic 5
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 6
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 7
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure

 

NEW QUESTION 12
An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.
Which action should the administrator take so the migration is successful?

  • A. Enable vCenter Single Sign-On Enhanced Linked Mode
  • B. Make sure that Witness traffic is on the management NIC.
  • C. Disable vSAN Deduplication and Compression
  • D. Reconfigure vCenter HA Admission control

Answer: A

 

NEW QUESTION 13
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

  • A. Delete the disk group(s) on the legacy host
  • B. Place the host in maintenance mode with no data migration
  • C. Place the host in maintenance mode with Ensure Accessibility
  • D. Disconnect from vCenter Server
  • E. Remove from vSAN cluster
  • F. Place the host in maintenance mode with Full Data migration

Answer: A,E,F

 

NEW QUESTION 14
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?

  • A. There will be no impact on performance.
  • B. The performance will be degraded.
  • C. The VMs will no longer be accessible.
  • D. The VMs will be in a suspended state.

Answer: A

 

NEW QUESTION 15
A cache disk failure marked a vSAN disk group as failed, and the data is being rebuilt on other disk groups.
Which action should the vSAN administrator take to reduce the negative impact on the VMs?

  • A. Enabling Resync Throttling
  • B. Setting the vSAN policy's IOPS limit for object value to 0 (unlimited)
  • C. Enabling Maintenance mode with no data evacuation
  • D. Enabling automatic rebalance

Answer: A

 

NEW QUESTION 16
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Obtain additional free capacity from the existing FC storage.
  • B. Create an HCI Mesh using the second cluster's datastore.
  • C. Create an HCI Mesh using the first cluster's datastore.
  • D. Obtain additional free capacity from the existing NAS storage.

Answer: D

 

NEW QUESTION 17
An administrator is planning to deploy workloads on a six node vSAN cluster, and all nodes are distributed equally across three racks.
Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?

  • A. Add two additional hosts per rack, and configure vSAN with three fault domains and FTT=1.
  • B. Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (erasure coding).
  • C. Add an additional host per rack, and configure vSAN with three fault domains and FTT=2.
  • D. Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (mirroring).

Answer: D

 

NEW QUESTION 18
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

  • A. 100% of the reads comes from vSAN hosts on the remote site
  • B. 50% of the reads comes from vSAN hosts on the remote site
  • C. 50% of the reads comes from vSAN hosts on the local site
  • D. 100% of the reads comes from vSAN hosts on the local site

Answer: D

 

NEW QUESTION 19
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?

  • A. Six nodes All-Flash vSAN cluster
  • B. Six nodes Hybrid vSAN cluster
  • C. Five nodes All-Flash vSAN cluster
  • D. Five nodes Hybrid vSAN cluster

Answer: A

 

NEW QUESTION 20
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

  • A. Promiscuous Mode
  • B. DVFiltering
  • C. MacLearning
  • D. Forged Transmits
  • E. Jumbo Frames

Answer: A,D

 

NEW QUESTION 21
An architect is working with vSAN and setting the fault domains to support FTT=1.
How many fault domains will be needed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 22
data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

  • A. Enable host build reserve.
    A minimum cluster of 4 vSAN nodes.
  • B. Enable performance services.
    A minimum cluster of 6 vSAN nodes.
  • C. Enable operations reserve.
    A minimum cluster of 3 vSAN nodes.
  • D. Enable IOInsight Metrics.
    A minimum cluster of 2 vSAN ROBO nodes.

Answer: A

 

NEW QUESTION 23
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?

  • A. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
  • B. Replace the caching device in each affected disk group.
  • C. Restore the communication with the KMS server, and re-establish the trust relationship.
  • D. Manually replace the Host Encryption Key (HEK) of each affected host.

Answer: C

 

NEW QUESTION 24
An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the dat a. Both vSAN clusters are managed by the same vCenter server.
What should the administrator configure?

  • A. iSCSI targets on vSAN
  • B. NFS volumes on vSAN
  • C. HCI Mesh on vSAN
  • D. vVOLs on vSAN

Answer: C

 

NEW QUESTION 25
An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.
Which requirement is specifically needed for these devices?

  • A. Write endurance
  • B. Read endurance
  • C. Capacity
  • D. IOPS

Answer: A

 

NEW QUESTION 26
An administrator has an absent capacity disk.
Which action, if any, should the administrator take to resolve the problem?

  • A. Verify the host is not isolated.
  • B. Wait, and vSAN will rebuild it.
  • C. Replace the faulty disk.
  • D. Replace the faulty host.

Answer: B

 

NEW QUESTION 27
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. PFTT = 0
  • B. SFTT = 1
  • C. PFTT = 1
  • D. SFTT = 0

Answer: D

 

NEW QUESTION 28
......

Latest 2022 Realistic Verified 5V0-21.21 Dumps: https://www.prep4pass.com/5V0-21.21_exam-braindumps.html

Pass Your  VMware 5V0-21.21 Exam with Correct 52 Questions and Answers: https://drive.google.com/open?id=1WbY4ngg5wT8Gs8N6Qee4gPT8Mm0ItG6C